XD2320 winding deformation frequency response detector

XD2320 winding deformation frequency response detector
Product Detailed
Related Categories:Testing Equipment
Winding deformation Frequency Response detector is for Power Transformer Diagnosis.

XD2320 winding deformation frequency response detector:

    Winding deformation Frequency Response detector is for Power Transformer Diagnosis. The XD2320 winding deformation frequency response detector detects transformer winding movements and mechanical failures due to mechanical shock, transportation or short circuits.

Detailed Specifiation:

    Output Voltage: 20Vpp (maximum, adjustable);

    Output impedance: 50Ω;

    Sweep range: 500Hz-2MHz;

    Scan mode: linear / logarithmic, interval can be set;

    Frequency accuracy: ≤0.01%;

    Selected frequency bandwidth: 0.5% measuring frequency;

    Detection range: -100dB-20dB;

    Detection accuracy: ±0.5dB;

Main Description:

 Model Name Features description
 XD2320 winding deformation  frequency response  detector Without display
 XD2320Y winding deformation  frequency response  detector With display

Application:

    Many dielectric and mechanical failures in large power transformers are preceded by mechanical changes in the winding structure. These changes, or displacements in the winding, may be the result of:

    Transportation damage occurring between the manufacturer and the final location.

    Short circuit forces imposed on the windings resulting from a low impedance fault occurring close to the transformer.

    Natural effects of aging on the insulating structures used to support the windings.

    Detection of these displacements ahead of a dielectric failure can reduce unplanned maintenance costs, and provide the possibility to improve system reliability by preventing outages. Additionally, when damage is discovered, repairs may be targeted to a specific phase winding.